Cookie preferences
This website uses cookies, which are necessary for the technical operation of the website and are always set. Other cookies, which increase the comfort when using this website, are used for direct advertising or to facilitate interaction with other websites and social networks, are only set with your consent.
ENESKApostprocess with electrical height adjustment incl. extraction with wet separator for reactive materials
By accessing the video you agree that your data will be
transmitted to YouTube and that you have read the
Privacy Policy.
Content:
1 piece(s)
- Order number: 0210012
- GTIN 4065735102807
- eClass 5.1: 21-10-13-90
- eClass 6.0: 21-10-13-90
- eClass 8.0: 21-10-90-90
- eClass 8.1: 36-23-90-01
The standard of safety during manual postprocessing is inadequate in many companies. Protective... more
Product information "ENESKApostprocess with electrical height adjustment incl. extraction with wet separator for reactive materials"
The standard of safety during manual postprocessing is inadequate in many companies. Protective suits are often only worn during individual working stages and are of no help against the risk of deflagration. Moreover, the working areas are not protected from invisible airborne dusts, which are usually underestimated. This is precisely where ENESKApostprocess from joke can help you.
Particular caution is required when processing reactive materials. In this case, it is not only the dusts that can ignite through friction; the material is also highly flammable and therefore carries higher risks of explosion and deflagration. A special moisture extractor with 5-fold filtration and explosion protection according to ATEX standard guarantees safe work. An integrated liquid bath binds the reactive particles which are thus unable to develop their explosive effect.
Titanium or aluminium are the common materials that most users recognised as reactive, but many alloys also have references to minimum ignition energy in their data sheets.
Are you not sure? We will be pleased to advise you.
• suitable for materials with a minimum ignition energy above one mJ
• with explosion protection according to ATEX standard
• moisture separator suitable for zone 22
• 5-fold filtration
• extraction capacity / volumetric flow: max. 350 m3/h
• materials to be processed: incl. among others aluminium and titanium
• incl. FSX automatic fine dust measuring system (for further information, see Order no. 0 210 306)
• with height adjustment
Particular caution is required when processing reactive materials. In this case, it is not only the dusts that can ignite through friction; the material is also highly flammable and therefore carries higher risks of explosion and deflagration. A special moisture extractor with 5-fold filtration and explosion protection according to ATEX standard guarantees safe work. An integrated liquid bath binds the reactive particles which are thus unable to develop their explosive effect.
Titanium or aluminium are the common materials that most users recognised as reactive, but many alloys also have references to minimum ignition energy in their data sheets.
Are you not sure? We will be pleased to advise you.
• suitable for materials with a minimum ignition energy above one mJ
• with explosion protection according to ATEX standard
• moisture separator suitable for zone 22
• 5-fold filtration
• extraction capacity / volumetric flow: max. 350 m3/h
• materials to be processed: incl. among others aluminium and titanium
• incl. FSX automatic fine dust measuring system (for further information, see Order no. 0 210 306)
• with height adjustment
Working chamber dimensions (W x D x H): | 930 x 790 x 250-600 mm |
Device dimensions (W x H x D): | 1300 x 1500 x 1790 mm |
Supply voltage: | 400 V / 16 A |
Weight [kg]: | 670 kg |
Lighting: | approx. 5,000K / approx. 3,300 lm, dimmable |
Design: | with height adjustment |